Observation Items
CO2 Budget of Forest
CO2 flux of forest:
Eddy covariance method using closed-path infra-red gas analyzer
CO2 concentration profile in forest canopy:
Time variation of CO2 concentration profile in forest community (5-8 levels)
Energy Budget in Forest
Radiation:
4 components measurement using pyranometer and pyrgeometer
Photosynthetically active radiation, PAR (Up- and down-ward above canopy; and down-ward under the crown)
Latent heat flux:
Band path covariance method using sonic anemometer-thermometer and thermohygrometer
Heat storage profile in canopy:
Temperature and humidity profile of air layer; soil temperature profile; and soil heat flux
Others
Air temperature and humidity profile above canopy, vertical profile of wind velocity
Latent heat and CO2 flux above forest canopy measured by open-path infra-red gas analyzer
Soil water content and sap flow
Biomass, soil respiration, tree photosynthesis and respiration

Example of Observation System
Turbulent Flux Observation
Sonic anemometer-thermometer | DAT-600 / KAIJO |
---|---|
Closed-path infra-red gas analyzer | LI-6262 / LI-COR |
Open-path infra-red gas analyzer | LI-7500 / LI-COR |
Thermohygrometer | HMP-155 / Vaisala; ventilated radiation shield ST-45 / Sanko Tsusho Co. Ltd. |
Gas sampling scanner | DSE-01A / Tokyo dylec Co. |
Low-pass filter | 3315 / NF Corporation |
Data logger | CR3000 / Campbell |
Observation items | 12-16 items including 3-D components of wind velocity, temperature, humidity, CO2 concentration |
---|---|
Sampling frequency | 5-10Hz |
Recording media | CF card (1-2GB) |

Micrometeorological Observation
Pyranometer | CM-6F, CM-6B / Kipp&Zonen |
---|---|
Pyrgeometer | PIR(Fan), PIR / Eppley |
PAR sensor | LI-190SA / LI-COR |
Thermohygrometer | HMP-155 / Vaisala; ventilated radiation shield ST-45 / Sanko Tsusho Co. Ltd. |
Anemometers | WMT52 / Vaisala |
Soil heat sensor | MF-81 / EKO |
Closed-path infra-red gas analyzer | LI-6262 / LI-COR |
Gas sampling scanner | DSG-08A / Tokyo dylec Co. |
Data logger | CR1000 / Campbell |
Sampling interval | 10s~30s |
---|---|
Recording interval | 5min~10min |
Recording media | Internal memory |
Power Supply Equipment
Denoising automatic voltage regulator (100V AC, 10A) | PSN-01 / DENKENSEIKI Research Institute Co., Ltd. |
---|---|
Uninterruptible power source | POWLI BX35XF / OMRON |
Standard Gases
LI-6262 reference | N2 (ZERO-A) / SUMITOMO SEIKA CHEMICALS CO., LTD. |
---|---|
Calibration | Air (ZERO-A) / SUMITOMO SEIKA CHEMICALS CO., LTD. |
CO2450ppm air balance / SUMITOMO SEIKA CHEMICALS CO., LTD. |
Observation Tower
Aluminium alloy tower: Nippon Light Metal Co., Ltd., UpRight Japn and ANDO Corporation
Iron self-supporting tower (API): ANDO Corporation