Portable Flux Observation System
System outline
We have developed a portable flux observation system with a view to provide an on-site reference for quality control of observed flux data and to standardize the measurement systems especially for new observation sites. The system adopts the eddy correlation method to measure fluxes of sensible heat, water vapor and carbon dioxide; and it consists of an ultrasonic anemometer-thermometer (CSAT3/ Campbell), a closed-path infrared gas analyzer (IRGA, LI-7000/ LI-COR), a thermo-hygrometer (HMP45A/ Vaisala), a high-speed sampling data logger (CR-3000/ Campbell), and an air intake switch for calibration. All devices are generally powered by 12 or 24V DC converted from 100 to 240V AC input. All components are mounted in a plastic container to improve portability and installation convenience.

Main unit
Equipments | Model, Manufacturer | Supply Voltage Consumption Current |
Infrared gas analyzer | LI-7000, LI-COR (USA) | 10.5 to 16VDC 4A max. |
---|---|---|
Ultrasonic anemometer-thermometer | CSAT3, Campbell (USA) | 10 to 16VDC 200mA |
Thermo-hygrometer | HMP45A, Vaisala (Finland) | 7 to 35VDC 4A max. |
Barometer | PTB-100A, Vaisala (Finland) | 10 to 30VDC 4mA max. |
Data logger | CR-3000, Campbell (USA) | 10 to 16VDC 10mA |
Draft fan for thermo-hygrometer | CF825D-12M, NIPPON BLOWER (Japan) | 12VDC 170mA |
Air pump | MVP03V12BA1, PANASONIC (Japan) | 8 to 15VDC 2.5A |
Mass flow controller | CMQ0020, YAMATAKE (Japan) | 15 to 24VDC 300mA max. |
Solenoid valve | AG31-02-2-03A, CKD (Japan) 2 valves are mounted | 12VDC 900mA each |
Flow meter | RK1650, KOFLOC (Japan) | - |
Filter | 9922-05, BLASTON (USA) | - |
Power unit
Equipments | Model, Manufacturer | Input and Output |
Switching Power Supply | PAA150F-12A, COSEL (Japan) | Input: 100 to 240VAC Output: 12V13A(max.) |
---|---|---|
Switching Power Supply | HWA050-24, SANKEN (Japan) | Input: 100 to 240VAC Output: 24V2.1A(max.) |

Observations Using Portable System
The portable system was installed in some observation sites to compare with the routine system to determine the relative difference among sites.
Previous observations
Portable flux observation system user manual
Click here for a sample of CR3000 control program. This sample program is in the public domain.
You can use it freely at your own responsibility. On no event will we be liable to you for any damages arising out of the use or inability to use the sample program.
Reference:
OHTANI Yoshikazu, MIZOGUCHI Yasuko, TAKANASHI Satoru, YASUDA Yukio, IWATA Hiroki, NAKAI Yuichiro, YUTA Satoko, YAMANOI Katsumi (2010): Development of a portable CO2 flux observation system using a closed-path gas analyzer for intercomparison. Bulletin of the Forestry and Forest Products Research Institute, 9(1):31-36.